The effect of residual electrode resistance and sampling delay on transient instability in the dynamic clamp system

Amanda J Preyer1, Robert J Butera

  • 1Laboratory for Neuroengineering, Georgia Tech/Emory University, School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0250, USA. ajervis@ece.gatech.edu

Related Concept Videos

Patch Clamp01:18

Patch Clamp

Many fundamental cell functions such as muscle contraction and nerve transmission rely on the electrical signals produced by the movement of positively and negatively charged ions across the cell membrane. One competent method to record current flowing across the whole cell or single ion channel is the patch-clamp technique.
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Transient and Steady-state Response01:24

Transient and Steady-state Response

In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state response.
Clamper Circuit01:14

Clamper Circuit

A clamper circuit, also known as a DC restorer, represents a specialized variant of the rectifier circuit, notable for its method of taking the output across the diode rather than the capacitor. This configuration lends to several distinctive applications, particularly in handling square wave inputs.
Within this circuit, the diode's orientation prompts the capacitor to charge up to the level of the most negative peak of the input signal. Upon reaching this state, the diode ceases to conduct,...
Voltammetry: Factors Affecting Measurements01:21

Voltammetry: Factors Affecting Measurements

A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...