Related Experiment Video
Updated: Jul 10, 2026

A Two-interval Forced-choice Task for Multisensory Comparisons
Published on: November 9, 2018
Theoretical comparison between the model-based and amplitude-based compliance estimation techniques
Jaak Talts1, Rein Raamat, Kersti Jagomägi
1Department of Physiology, University of Tartu, Estonia. jaak.talts@ut.ee
Abstract:
A theoretical study has been performed to assess how the pulse pressure variation affects results of the arterial compliance measurement. Two asymmetric arctangent models for the arterial pressure-volume (P-V) relationship have been used by applying model-based and amplitude-based compliance estimation techniques. The results demonstrate that for near-zero transmural pressure the model-based values of the compliance are systematically higher than those estimated by the amplitude-based calculation technique. Increasing of the pulse pressure amplitude causes a considerable reduction in the amplitude-based compliance estimate. For a P-V relationship with a lower steepness, a reduction in the amplitude-based compliance versus transmural pressure is smaller.
Related Concept Videos
Modeling and Similitude
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
Electronic Distance Measuring Instruments
Mechanistic Models: Compartment Models in Individual and Population Analysis
Typical Model Studies