Ultrasound-based Pulse Wave Velocity Evaluation in Mice
Published on: February 14, 2017
A coronary pulse wave velocity measurement system.
Taewoo Nam1, Jongman Cho, Junghyeon Choi
1Department of Biomedical Engineering, Inje University, Gimhae, 621-749, Republic of Korea. ntw99@bse.inje.ac.kr
Summary
A new system accurately measures coronary arterial pulse wave velocity (PWV) in real-time. This advancement simplifies assessing arterial dynamics, with average PWV found to be 934.764 cm/sec in clinical trials.
Area of Science:
- Cardiovascular physiology
- Medical engineering
- Diagnostic technology
Background:
- Pulse wave velocity (PWV) is crucial for understanding arterial pressure and flow dynamics.
- Manual measurement of coronary arterial PWV is challenging due to difficulties in determining transmission time.
- Existing methods lack real-time capabilities for coronary arterial PWV assessment.
Purpose of the Study:
- To develop a system for real-time measurement of coronary arterial pulse wave velocity (PWV).
- To validate the accuracy of the developed system through clinical experiments.
- To establish a reliable method for assessing coronary arterial hemodynamics.
Main Methods:
- Development of an automated system for real-time PWV measurement.
- Recording of pulse wave and electrocardiogram (ECG) data.
- Clinical validation of the system in patients to measure coronary arterial PWV.
Main Results:
- Successful development of a system for real-time PWV measurement.
- Clinical experiments validated the accuracy of the measured coronary arterial PWV.
- The average measured coronary arterial PWV was 934.764 ± 104.606 cm/sec.
Conclusions:
- The developed system enables accurate, real-time measurement of coronary arterial PWV.
- This technology offers a significant improvement over manual methods for assessing arterial stiffness.
- The findings provide a valuable new tool for cardiovascular research and clinical practice.
More Related Videos
Related Concept Videos
Pulse
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical indicator...
The pulse serves as a clinical indicator...
Pulse
The pulse is one of the most fundamental physiological indicators of the body's cardiovascular health. It is the rhythmic expansion and contraction of the arterial walls in response to the pressure generated by the heart's pumping action.
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Special considerations while measuring pulse
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
Equipments Used To Measure Blood Pressure
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of radial pulse
Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: