Ultrasound Assessment of Endothelial Function: A Technical Guideline of the Flow-mediated Dilation Test
Published on: April 27, 2016
Assessment of endothelial function in the radial artery using inhaled albuterol
Bin Huang1, Kathleen M Brennan, Thomas F Budinger
1Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA. BHuang@lbl.gov
Abstract:
Endothelial dysfunction is an early indicator of developing atherosclerosis and is a strong predictor of future heart attack and stroke. At present, evaluation of endothelial function (EF) (specifically, EF mediated by nitric oxide, NO) is too technically difficult to form part of a routine clinical examination. Non-invasive methods that measure NO-dependent EF in arteries make use of a 4-5 minute blood pressure cuff occlusion of the arm in order to induce reactive hyperemia (RH) upon cuff release. The increased blood flow that results from the RH stimulates the endothelial cells to release NO and relax the surrounding vascular smooth muscle. The magnitude of the change in arterial caliber or stiffness provides a measure of EF. The cuff occlusion is uncomfortable and inflation and release inevitably move the arm, increasing the technical difficulty of obtaining reliable measurements. In beta2-adrengergic agonist albuterol induces NO-mediated vasorelaxation in resistance vessels of humans. We examine, for the first time, the effect of albuterol on conduit vessels (radial artery) by measuring changes in the transit times of artificial pulses observed after inhalation of albuterol. We conclude that albuterol is able to relax the radial artery and that this correlates with the effects of RH (r=0.62, p=0.04). However, the response to a dose of 360 micro-g is smaller and more variable when compared to the response to RH-based stimulus.
Related Concept Videos
06:35Ultrasound Assessment of Endothelial Function: A Technical Guideline of the Flow-mediated Dilation Test
07:25Assessing Murine Resistance Artery Function Using Pressure Myography
05:41Non-invasive Assessment of Microvascular and Endothelial Function
07:46Assessing Endothelial Vasodilator Function with the Endo-PAT 2000
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
02:43Assessing Mitochondrial Function in Cerebral Vascular Endothelial Cells