Comparison and co-relation of invasive and noninvasive methods of ejection fraction measurement
Darshan Godkar1, Kalyan Bachu, Bijal Dave
1RN6N2, Department of Cardiology, 2601 Ocean Parkway, Coney Island Hospital, Brooklyn, NY 11235, USA. darshangodkar@yahoo.com
Background:
Accurate estimation of left ventricular ejection fraction (LVEF) has assumed great significance in the era of automatic implantable cardioverter defibrillators (AICDs), and a low EF may be one of the sole deciding factor in determining AICD implantation in certain patient populations.
Aim:
There are various methods, invasive and noninvasive, which can help calculate EF. We sought to conduct a retrospective study comparing EF estimation by invasive (angiography) and noninvasive methods [MUGA (multiple-gated acquisition), echocardiography (echo), single-photon emission computed tomography (SPECT)] in 5,558 patients in our hospital from 1995-2004.
Methods And Results:
EF was estimated by > or = 1 method (angiography, MUGA, echo, SPECT) within a one-month period. Values for the four tests in 5,558 patients were as follows: angiography mean 46.2, range 20-75, standard deviation (SD) 13.1; MUGA mean 45.7, range 20-70, SD 11.6; echo mean 45.7, range 22-70, SD 11.2; and SPECT mean 54.4, range 30-75, SD 11.9. Excellent positive correlations were found among all four tests as follows: angiography and MUGA, correlation coefficient (r) = 0.97, angiography and echo r = 0.96, angiography and SPECT r = 0.94, MUGA and echo r = 0.97, MUGA and SPECT r = 0.94, and echo and SPECT r = 0.94. Values for SPECT were significantly higher than for angiography, echo and MUGA (p < 0.001). The arithmetic difference between angiography and MUGA (mean 0.50, range -5.0-5.0) and the arithmetic difference between angiography and echo (mean 0.52, range -5.0-15.0) were similar (p = 0.59). The arithmetic difference between SPECT and angiography (mean 8.2, range -15.0-20.0) was significantly larger than the arithmetic difference between angiography and echo (p < 0.001).
Conclusions:
All the four methods used to estimate EF corelate well with each other. However, values estimated during stress testing by SPECT overestimate EF and are significantly higher as compared to MUGA, echo and angiography. Estimation of EF by MUGA, echo or angiography should be preferred over SPECT, especially when that patient warrants intervention. We conclude that the overestimation of EF by SPECT may deprive some deserving patients of the survival benefit afforded by ICD.
More Related Videos
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
12:12Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...