Liquid chromatography/multi-stage mass spectrometry of bisphenol A and its halogenated derivatives
Héctor Gallart-Ayala1, Encarnación Moyano, Maria T Galceran
1Department of Analytical Chemistry, University of Barcelona, Martí i Franquès 1-11, 08028 Barcelona, Spain.
Abstract:
We report a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for analyzing bisphenol A (BPA) and its halogenated derivatives. Since only tetrachlorobisphenol A and tetrabromobisphenol A (TBBPA) are commercially available, mono-, di- and trichlorobisphenol A were synthesized and purified in order to be used as analytical standards. This family of compounds was studied using electrospray ionization and an ion trap mass analyzer in order to characterize the new compounds and to propose fragmentation pathways. Multi-stage mass spectrometry was used to confirm the genealogical relationship between the ions. Some product ions were traced from MS/MS to MS(4) and the labelled compounds BPA-d(16) and TBBPA-(13)C(12) were used to assign some product ion structures. In general, the deprotonated molecule [M--H](-) loses a methyl and/or a halogen group during both MS/MS and MS(3), while the neutral loss of CO was also observed in MS(3) spectra. We selected the most intense and characteristic MS/MS transitions for LC/MS/MS analysis. LC separation was performed in a reversed-phase column; methanol/water (no additives) was used as the mobile phase in gradient elution mode; and BPA-d(16) was chosen as the internal standard. Solid-phase extraction (SPE) was used to pre-concentrate and to clean up water samples. The SPE LC/MS/MS method allows BPA and its halogenated derivatives to be detected at a few parts-per-billion (ppb) in surface water.
More Related Videos
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Alkyl Halide Fragmentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Cycloalkane Fragmentation
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...
