A new water-soluble near-neutral ratiometric fluorescent pH indicator

Sheng Yao1, Katherine J Schafer-Hales, Kevin D Belfield

  • 1Department of Chemistry and CREOL, College of Optics and Photonics, University of Central Florida, PO Box 162366, Orlando, Florida 32816-2366, USA.

Organic Letters
|November 23, 2007
PubMed

Related Concept Videos

Indicators02:39

Indicators

Certain organic substances change color in dilute solution when the hydronium ion concentration reaches a particular value. For example, phenolphthalein is a colorless substance in any aqueous solution with a hydronium ion concentration greater than 5.0 × 10−9 M (pH < 8.3). In more basic solutions where the hydronium ion concentration is less than 5.0 × 10−9 M (pH > 8.3), it is red or pink. Substances such as phenolphthalein, which can be used to determine the pH of a solution, are called...
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
Titration of Polyprotic Base with a Strong Acid01:18

Titration of Polyprotic Base with a Strong Acid

The titration of a polyprotic base such as sodium carbonate with a strong acid such as hydrochloric acid results in two equivalence points on the titration curve. At the first equivalence point, the carbonate ions in the base are completely converted to bicarbonate ions. The second equivalence point corresponds to the complete conversion of bicarbonate ions to carbonic acid, which dissociates into carbon dioxide and water. The region before the first equivalence point corresponds to the...