Estimating viral concentrations from dilution counts: a reliable computation method programmed on a pocket

P Roussel1, J Husson

  • 1IMEC v.z.w., Département MAP/ARS, Heverlee, Belgium.

Journal of Virological Methods
|September 1, 1991
PubMed
Summary

This study presents a calculator program for estimating infective particle density using maximum likelihood. The program automates dilution selection and provides variance estimates and confidence intervals for accurate results.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

New insights into the electronic structure of<i>α</i>-U and<i>δ</i>-Pu.

Journal of physics. Condensed matter : an Institute of Physics journal·2023
Same author

Design of a multi-well plate for high-throughput characterization of heterogeneous catalysts by XRD, FT-IR, Raman and XRF spectroscopies.

RSC advances·2022
Same author

Anhydrous Phase B: Transmission Electron Microscope Characterization and Elastic Properties.

Geochemistry, geophysics, geosystems : G(3)·2019
Same author

Positive non-linear capacitance: the origin of the steep subthreshold-slope in ferroelectric FETs.

Scientific reports·2019
Same author

Synthesis and structural characterization of the first neptunium based metal-organic frameworks incorporating {Np<sub>6</sub>O<sub>8</sub>} hexanuclear clusters.

Chemical communications (Cambridge, England)·2018
Same author

Hepatitis C genotype change after transplantation utilizing hepatitis C positive donor organs.

Transplant infectious disease : an official journal of the Transplantation Society·2018

Area of Science:

  • Microbiology
  • Biostatistics
  • Computational Biology

Background:

  • Accurate estimation of infective particle density is crucial for biological and medical research.
  • Traditional methods for density estimation can be labor-intensive and prone to errors.
  • Statistical tables are often required for analysis, limiting accessibility.

Purpose of the Study:

  • To develop a user-friendly program for estimating infective particle density.
  • To implement the maximum likelihood method for enhanced accuracy.
  • To automate the selection of suitable dilutions and statistical analysis.

Main Methods:

  • A program was developed for the Hewlett-Packard 41C calculator.
  • The maximum likelihood method was applied for density estimation.

Related Experiment Videos

  • Automated testing for overcrowding and clumping was incorporated.
  • Main Results:

    • The program provides an unbiased estimate for the variance of the density.
    • A suitable confidence interval and its corresponding confidence level are calculated.
    • Automated selection of dilutions eliminates the need for statistical tables.

    Conclusions:

    • The developed program offers an efficient and accurate method for infective particle density estimation.
    • Automation of dilution selection simplifies the analysis process.
    • The program enhances the reliability of results in microbiological studies.