Effectiveness of contamination prevention procedures in a trace explosives laboratory

Matthew S Beardah1, Sean P Doyle, Charlotte E Hendey

  • 1Forensic Explosives Laboratory, Defence Science and Technology Laboratory, Fort Halstead, Sevenoaks, Kent, TN14 7BP, United Kingdom. msbeardah@dstl.gov.uk

Related Concept Videos

Contaminants and Errors01:16

Contaminants and Errors

Effective sample preparation is crucial for accurate and reliable laboratory analysis. During this process, two significant sources of error can arise: concentration bias from improper sample splitting and contamination caused by methods used to reduce particle size, such as grinding or homogenization. Identifying and minimizing these potential errors is crucial to ensuring the validity of the analysis.
Another key consideration is determining the appropriate number of samples required to...
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...