Radial modulation of microbubbles for ultrasound contrast imaging
Ayache Bouakaz1, Michel Versluis, Jerome Borsboom
1Inserm U619, Tours, France. bouakaz@med.univ-tours.fr
Abstract:
Over the past few years, extensive research has been carried out in the field of ultrasound contrast imaging. In addition to the development of new types of ultrasound contrast agents, various imaging methods dedicated to contrast agents have been introduced, and some of them are now commercially available. In this study, we present results of an imaging technique that is capable of detecting echoes from microbubbles and eliminating those emanating from nonoscillating structures (tissue), thereby enhancing contrast imaging. The method is based on mixing a low frequency (LF) modulator signal and a high frequency (HF) imaging signal to effectively modulate the size of the contrast microbubble through its volumetric oscillations using the LF signal and to probe the radial motion using the HF imaging signal. To evaluate the performances and limitations of the method, high-speed optical observations and acoustic measurements were carried out on soft-shelled microbubbles. The results showed that, by incorporating the modulator signal, the bubbles respond differently compared to the HF excitation alone. The decorrelation between the signals obtained at the compression and expansion phase of the modulator signal is significantly high to be used as a parameter to detect contrast microbubbles and discriminate them from tissue. The echo received from a solid reflector shows identical responses during the compression and rarefaction phase of the LF signal. In conclusion, these results demonstrate the feasibility of this fully linear approach for improving the contrast detection.
Related Concept Videos
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...