Related Experiment Video
Updated: Jul 9, 2026

Measurement of the Hand Transmitted Vibration of the Human Hand Arm System During Operation of a Hand Tractor
Published on: June 16, 2021
Digital blood flow and temperature responses in palmar and dorsal skin induced by short-term vibration exposure while
1Department of Hygiene, Yamaguchi University School of Medicine, Ube 755-8505, Japan.
Objective:
The present study was designed to examine the simultaneous responses in digital circulation at both palmar and dorsal skin induced by acute exposure to short-term vibration while grasping a vibratory handle, and also to evaluate the importance of measurement site for such responses.
Methods:
Finger blood flow (FBF) and finger skin temperature (FST) were measured from the palmar (index finger) and dorsal (middle finger) regions of the right hand in eight male subjects, at rest for 5 min and while gripping the handle for 15 min. At the end of fifth minute during grasping of the handle, subject's hand was exposed for 5 min to four different exposure conditions (vibration at three frequencies of 31.5, 125 and 250 Hz with a frequency weighted rms acceleration of 5.5 m/s(2), and no vibration).
Results:
During vibration exposure relative to the corresponding control conditions, the %change (calculated from before exposure mean value in gripping condition) in dorsal FBF increased substantially (P < 0.01-0.001), and the %change for decreased palmar FST augmented significantly (P < 0.05-0.01) in all frequencies. After vibration exposure, blood flow and skin temperature also remained significantly higher in dorsal finger (P < 0.05-0.005), and significantly lower in palmar finger (P < 0.005-0.001) at different frequencies comparing to the control values. Also, only vibration exposure caused significantly different %changes in digital circulation between palmar and dorsal fingers (P < 0.001).
Conclusion:
These data suggest that vibration can affect the digital circulation in both palmar and dorsal skin but differently. Therefore, while comparing the data of digital circulatory responses induced by acute exposure to hand-transmitted vibration recorded at palmar and dorsal sides of the hand, cautions are required when interpreting the results.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Responses to Heat and Cold Stress