Related Experiment Video
Updated: Jul 9, 2026

Automated Hospital Room Disinfection Utilizing a Novel Aerosolized Hydrogen Peroxide Microdroplet Disbursing Technology
Published on: February 24, 2026
Airflow and droplet spreading around oxygen masks: a simulation model for infection control research
Margaret Ip1, Julian W Tang, David S C Hui
1Centre for Emerging Infectious Diseases, School of Public Health, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China.
Background:
Respiratory assist devices, such as oxygen masks, may enhance the potential to spread infectious aerosols from patients with respiratory infections.
Methods:
A technique was developed to visualize exhaled aerosols during simulated patients' use of oxygen masks in a health care setting and tested using the simple, the nonrebreathing, and the Venturi oxygen masks. A smoke tracer was introduced into one of the lungs of the model to enable it to mix with the incoming oxygen and then to be further inhaled/exhaled by the model according to a variety of realistic respiratory settings (14, 24, and 30 breaths per minute, with tidal volumes of 500, 330, 235 mL, respectively) and oxygen supply flow rates (between 6 and 15 liters per minute). Digital recordings of these exhaled airflow patterns allowed approximate distances to be estimated for the extent of the visible exhaled air plumes emitted from each oxygen mask type at these settings.
Results:
It was found that the simple, the nonrebreathing, and the Venturi-type oxygen masks produced exhaled smoke plumes over minimum distances of 0.08 to 0.21 m, 0.23 to 0.36 m, and 0.26 to 0.40 m, respectively.
Conclusion:
Health care workers may therefore consider any area within at least 0.4 m of a patient using such oxygen masks to be a potential nosocomial hazard zone.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Bioreactor Controls-II
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Physical Principles Governing Gas Exchange
Gas Laws Governing Respiration
The behavior of gases is guided by Dalton's Law of partial pressures and Henry's Law.
Dalton's Law asserts that the total pressure exerted by...