Evaluation of band broadening in chemiluminescence detection coupled to pressurized capillary electrochromatography with an off-column coaxial flow interface
Related Experiment Video
Updated: Jul 9, 2026

Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Zian Lin1, Jian Lin, Xiaoping Wu
1Department of Chemistry, Fuzhou University, Fuzhou, People's Republic of China.
Abstract:
A system of off-column coaxial flow chemiluminescence (CL) detection coupled to pressurized CEC (pCEC) was described. The interface utilized a reactor that introduced postcolumn CL reagent into the capillary effluents in a sheathing flow profile. To compare and evaluate band broadening of analytes caused by the detector, the typical CL compounds luminol and N-(4-aminobutyl)-N-ethylisoluminol (ABEI) were separated and detected by pCEC or capillary HPLC (cHPLC) coupled to CL and UV detector, respectively. The results demonstrated that the band broadening caused by off-column detection interface was minimized due to the fast kinetic nature of the CL reaction. With the proposed pCEC-CL system, the detection limits of luminol and ABEI were 1.0x10(-8) and 8.0x10(-8) mol/L, respectively, which were approximately 100-fold more sensitive than those obtained with UV absorption. In addition, separation and detection of the ABEI-labeled L-lysine (L-Lys) and L-arginine (L-Arg) were accomplished by pCEC-CL method based on the principle of ABEI-potassium ferricyanide-alkaline medium CL reaction system. Under the optimum conditions, good results could be achieved compared with pCEC-UV.
More Related Videos
13:36Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
14:12Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System
Published on: November 21, 2023
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Types of Detectors-II