John W McMurdy1, Gregory D Jay, Selim Suner
1Division of Engineering, Brown University, Providence, RI 02912, USA. john_mcmurdy@brown.edu
Background:
Anemia is an underdiagnosed, significant public health concern afflicting >2 billion people worldwide. The detrimental effects of tissue oxygen deficiency on the cardiovascular system and concurrent appearance of anemia with numerous high-risk disorders highlight the importance of clinical screening. Currently there is no universally accepted, clinically applicable, noninvasive hemoglobin/hematocrit screening tool. The need for such a device has prompted an investigation into a breadth of techniques.
Methods:
A synopsis of the literature and current directions of research in noninvasive total hemoglobin measurement was collected. Contributions highlighted in this review are limited to those studies conducted with a clinical aspect, and most include in vivo patient studies.
Results:
The review of potential techniques presented here includes optoacoustic spectroscopy, spectrophotometric imaging, diffuse reflectance spectroscopy, transcutaneous illumination, electrical admittance plethysmography, and photoplethysmography. The technological performance, relative benefits of each approach, potential instrumentation design considerations, and future directions are discussed in each subcategory.
Conclusions:
Many techniques reviewed here have shown excellent accuracy, sensitivity, and specificity in measuring hemoglobin/hematocrit, thus in the near future a new clinically viable tool for noninvasive hemoglobin/hematocrit monitoring will likely be widely used for patient care. Limiting factors in clinical adoption will likely involve technology integration into the current standard of care in each field routinely dealing with anemia.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.