Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Delta down compared with delta pulse pressure as an indicator of volaemia during intracranial surgery
E Deflandre1, V Bonhomme, P Hans
1University Department of Anaesthesia and Intensive Care Medicine, CHR de la Citadelle, Bd du 12eme de Ligne, 1, 4000 Liege, Belgium. eric.deflandre@gmail.com
Background:
Delta pulse pressure (DPP) and delta down (DD) are indicators of volaemia. The threshold value of DPP for discriminating between responders and non-responders to fluid loading (FL) is 13%. This study aimed at comparing DD with DPP during intracranial surgery.
Methods:
Twenty-six adult patients undergoing scheduled intracranial surgery under general anaesthesia were enrolled. DD and DPP were simultaneously measured every 10 min. A DPP>13% on two consecutive occasions prompted a 250 ml FL. Pairs of data were analysed using regression analysis, receiver operating characteristics (ROC) curve, and prediction probability (Pk).
Results:
We found a significant correlation between DD and DPP (R2=0.5431, P<0.001). ROC curve analysis revealed an excellent accuracy of DD in predicting a DPP value higher or lower than 13% (area under the curve: 0.967, se: 0.013). The DD threshold associated with the best sensitivity (0.90) and specificity (0.99) was 5 mm Hg. The Pk of DD to predict a DPP value higher or lower than 13% was 0.97 (se: 0.01). A total of 41 FL performed in 19 patients resulted in a decrease of DD and DPP below 5 mm Hg and 13%, respectively, in all but one occasion.
Conclusions:
DD is as efficient as DPP to assess hypovolaemia and predict responsiveness to FL in patients undergoing intracranial surgery. A 5 mm Hg DD value can be considered as a valuable threshold for initiating FL. These results support its use during intracranial surgery.
Related Concept Videos
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Increased Intracranial Pressure l: Introduction
Blood Pressure
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...