Development of an algorithm for surveillance of ventilator-associated pneumonia with electronic data and comparison
Michael Klompas1, Ken Kleinman, Richard Platt
1Department of Ambulatory Care and Prevention, Harvard Medical School, Boston, Massachusetts, USA. mklompas@partners.org
Objective:
Surveillance for ventilator-associated pneumonia (VAP) using standard Centers for Disease Control and Prevention (CDC) criteria is labor intensive and involves many subjective assessments. We sought to improve the efficiency and objectivity of VAP surveillance by adapting the CDC criteria to make them amenable to evaluation with electronic data.
Design:
Prospective comparison of the accuracy of VAP surveillance by use of an algorithm with responses to prospective queries made to intensive care physicians. CDC criteria for VAP were used as a reference standard to evaluate the algorithm and clinicians' reports.
Setting:
Three surgical intensive care units and 2 medical intensive care units at an academic hospital.
Methods:
A total of 459 consecutive patients who received mechanical ventilation for a total of 2,540 days underwent surveillance by both methods during consecutive 3-month periods. Electronic surveillance criteria were chosen to mirror the CDC definition. Quantitative thresholds were substituted for qualitative criteria. Purely subjective criteria were eliminated. Increases in ventilator-control settings were taken to indicate worsening oxygenation. Semiquantitative Gram stain of pulmonary secretion samples was used to assess whether there was sputum purulence.
Results:
The algorithm applied to electronic data detected 20 patients with possible VAP. All cases of VAP were confirmed in accordance with standard CDC criteria (100% positive predictive value). Prospective survey of clinicians detected 33 patients with possible VAP. Seventeen of the 33 possible cases were confirmed (52% positive predictive value). Overall, 21 cases of confirmed VAP were identified by either method. The algorithm identified 20 (95%) of 21 known cases, whereas the survey of clinicians identified 17 (81%) of 21 cases.
Conclusions:
Surveillance for VAP using electronic data is feasible and has high positive predictive value for cases that meet CDC criteria. Further validation of this method is warranted.
More Related Videos
07:31Implementation of a Real-Time Psychosis Risk Detection and Alerting System Based on Electronic Health Records using CogStack
Published on: May 15, 2020
04:32Murine Oropharyngeal Aspiration Model of Ventilator-associated and Hospital-acquired Bacterial Pneumonia
Published on: June 28, 2018
Related Concept Videos
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Pneumonia III: Complications and Assessment
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed....
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Principles of Disease Surveillance