Related Experiment Video
Updated: Jul 8, 2026

Fabric Moisture Uniform Control to Study the Influence of Air Impingement Parameters on Fabric Drying Characteristics
Published on: August 19, 2019
Apparent evaporative resistance at critical conditions for five clothing ensembles
Victor Caravello1, Elizabeth A McCullough, Candi D Ashley
1College of Public Health, University of South Florida, Tampa, FL 33612-3805, USA.
Abstract:
A limiting factor for clothing ensembles inherent during heat stress exposures is the evaporative resistance, which can be used to compare candidate ensembles and in rational models of heat exchange. In this study, the apparent total evaporative resistance of five clothing ensembles (cotton work clothes, cotton coveralls, and coveralls made of Tyvek 1424 and 1427, NexGen and Tychem QC was estimated empirically from wear trials using a progressive heat stress protocol and from clothing insulation adjustments based on ISO 9920 (2007) and wetness. The metabolic rate was moderate at 165 W m(-2) and relative humidity was held at 50%. Twenty-nine heat-acclimated participants (20 men and 9 women) completed trials for all clothing ensembles. A general linear mixed effects model (ensemble and participants as a random effect) was used to analyze the data. Significant differences (p < 0.0001) among ensembles were observed for apparent total evaporative resistance. As expected, Tychem QC had the highest apparent total evaporative resistance at 0.033 kPa m(2) W(-1). NexGen was next at 0.017 kPa m(2) W(-1). These were followed by Tyvek 1424 at 0.015 kPa m(2) W(-1), and Tyvek 1427, Cotton Coveralls and Work Clothes all at 0.013 kPa m(2) W(-1). This wear test method improves on past methods using the progressive protocol to determine evaporative resistance by including the effects of movement, air motion and wetness on the estimate of clothing insulation. The pattern of evaporative resistance is the same as that for critical WBGTs and a linear relationship between apparent total evaporative resistance and WBGT clothing adjustment factor is suggested. With the large sample size, a good estimate of sample variance associated with progressive method can be made, where the standard error is 0.0044 kPa m(2) W(-1) with a 95% confidence interval of 0.0040-0.0050 kPa m(2) W(-1).
Related Concept Videos
Adaptations that Reduce Water Loss
Clausius-Clapeyron Equation
Physical Principles Governing Gas Exchange
Gas Laws Governing Respiration
The behavior of gases is guided by Dalton's Law of partial pressures and Henry's Law.
Dalton's Law asserts that the total pressure exerted by...
Requirements for Human Life
Oxygen
Atmospheric air is only about 20 percent oxygen, but that oxygen is a key component of the chemical reactions that keep the body alive, including the reactions that produce ATP. Brain cells are susceptible to a lack of oxygen because they require a...
Boundary Layer Characteristics
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...

