Risk of hand or glove contamination after contact with patients colonized with vancomycin-resistant enterococcus or
Mary K Hayden1, Donald W Blom, Elizabeth A Lyle
1Rush University Medical Center, Chicago, Illinois 60612, USA. mhayden@rush.edu
Objective:
To estimate the level of hand or glove contamination with vancomycin-resistant enterococci (VRE) among healthcare workers (HCWs) who touch a patient colonized with VRE and/or the colonized patient's environment during routine care.
Design:
Structured observational study.
Setting:
Medical intensive care unit of a 700-bed, tertiary-care teaching hospital.
Participants:
VRE-colonized patients and their caregivers.
Methods:
We obtained samples from sites on the intact skin of 22 patients colonized with VRE and samples from sites in the patients' rooms, before and after routine care, during 27 monitoring episodes. A total of 98 unique HCWs were observed during 131 HCW observations. Observers recorded the sites touched by HCWs. Culture samples were obtained from HCWs' hands and gloves before and after care.
Results:
VRE were isolated from a mean (+/-SD) of 55% +/- 24% of patient sites (n=256) and 17% +/- 12% of environmental sites (n=1,572). Most HCWs (131 [56%]) touched both the patient and the patient's environment; no HCW touched only the patient. Of 103 HCWs whose hand samples were negative for VRE when they entered the room, 52% contaminated their hands or gloves after touching the environment, and 70% contaminated their hands or gloves after touching the patient and the environment (P=.101). In a univariate logistic regression model, the risk of hand or glove contamination was associated with the number of contacts made (odds ratio, 1.1 [95% confidence interval, 1.01-1.19). In a multivariate model, the effect of the number of contacts could not be distinguished from the effect of type of contact (ie, touching the environment alone or touching both the patient and the environment). Overall, 37% of HCWs who did not wear gloves contaminated their hands, and 5% of HCWs who wore gloves did so (an 86% difference).
Conclusion:
HCWs were nearly as likely to have contaminated their hands or gloves after touching the environment in a room occupied by a patient colonized by VRE as after touching the colonized patient and the patient's environment. Gloves were highly protective with respect to hand contamination.
Related Concept Videos
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Hand hygiene
Hand washing...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin create...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...