Automatic phasing of MR images. Part I: linearly varying phase

G Larry Bretthorst1

  • 1Biomedical Magnetic Resonance Laboratory, Department of Radiology, Washington University, Campus Box 8227, 525 Scott Avenue, Suite 2313, St. Louis, MO 63110, USA. gbretthorst@wustl.edu <gbretthorst@wustl.edu>

Related Concept Videos

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences01:17

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences

A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
The Phase Rule01:20

The Phase Rule

The phase rule describes the relationship between the variance (degrees of freedom), the number of components, and the number of phases in a system at equilibrium.Variance is a concept that denotes the number of independent intensive properties (properties are those that do not depend on the amount of material in the system), such as temperature, pressure, and composition, that can be altered without impacting the number of phases in equilibrium.In a single-component system, such as pure water,...