Related Experiment Video
Updated: Jul 8, 2026

Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Arterial oxygenation and one-lung anesthesia
Andrew Ian Levin1, Johan Francois Coetzee, Andre Coetzee
1Department of Anesthesiology and Critical Care, University of Stellenbosch and Tygerberg Academic Hospital, South Africa. ail@sun.ac.za
Purpose Of Review:
In the presence of the obligatory shunt during one-lung ventilation, arterial oxygenation is determined by the magnitude of the shunt in addition to the oxygen content of the mixed venous blood coursing through that shunt. The present discussion aims to heighten awareness of factors determining arterial oxygenation during one-lung anesthesia, other than the magnitude of the shunt and dependent lung low-ventilation perfusion units.
Recent Findings:
A convenient way to increase mixed venous and thereby arterial oxygenation is to raise cardiac output. While this approach has achieved some success when increasing cardiac output from low levels, other studies have highlighted limitations of this approach when cardiac output attains very high levels. The effect of anesthesia techniques on the relationship between oxygen consumption and cardiac output could also explain unanswered questions regarding the pathophysiology of arterial oxygenation during one-lung anesthesia.
Summary:
The effects of anesthesia techniques on oxygen consumption, cardiac output and therefore mixed venous oxygenation can significantly affect arterial oxygenation during one-lung anesthesia. While pursuing increases in cardiac output may, under limited circumstances, benefit arterial oxygenation during one-lung ventilation, this approach is not a panacea and does not obviate the necessity to optimize dependent lung volume.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
