Normal values for manometry performed with swallows of viscous test material
Wojciech Blonski1, Marcelo Vela, Amine Hila
1Division of Gastroenterology, Medical University of South Carolina, Charleston, South Carolina, USA. blonskiw@musc.edu
This study establishes normal manometric values for viscous swallows, crucial for diagnosing esophageal motility disorders. These findings improve the accuracy of esophageal function testing using combined multichannel intraluminal impedance and manometry (MII-EM).
Area of Science:
- Gastroenterology
- Esophageal Physiology
- Diagnostic Testing
Background:
- Esophageal function testing often uses combined multichannel intraluminal impedance and manometry (MII-EM).
- Current manometric diagnoses rely solely on liquid swallows, potentially limiting accuracy.
- Establishing normal values for viscous swallows is essential for comprehensive esophageal assessment.
Purpose of the Study:
- To determine normal manometric values for esophageal function testing using viscous boluses.
- To enhance the diagnostic capabilities of MII-EM by incorporating viscous swallow data.
- To provide a standardized reference for interpreting manometric findings with viscous swallows.
Main Methods:
- Analysis of MII-EM studies from 80 healthy volunteers.
- Evaluation of manometric parameters including contraction amplitude, duration, distal onset velocity, and LES residual pressure.
- Comparison of parameters between liquid and viscous swallows.
Main Results:
- Viscous swallows showed higher contraction amplitudes and LES residual pressures compared to liquid swallows.
- Contraction duration was similar for both liquid and viscous swallows.
- Normal upper limits for viscous swallows were established: DEA <204 mmHg, LES residual pressure
Conclusions:
- Recommended normal values for manometry with viscous swallows include
- These values provide a normative reference for esophageal manometry using viscous boluses.
- This study contributes to more accurate esophageal motility disorder diagnosis.
Related Concept Videos
Urodynamic Studies: Uroflowmetry
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Imaging Studies VI: Voiding Cystourethrography and Cystography
Assessment of the Gastrointestinal System I: Subjective Data
Health History
The initial step in assessing the GI system is obtaining a comprehensive health history. This includes inquiring about the patient's history or presence of problems related to...