Performance study of single-slice positron emission tomography scanners by monte carlo techniques
Abstract:
A Monte Carlo simulation of the gamma ray transport within a single-slice positron emission tomograph has been generated to study the effects of system parameters on performance. Included in the simulation are the radioactive source distribution, collimators, and detectors with intercrystal septa. Data are first presented to show the coincidence and singles sensitivities as a function of ring radius. Then, for a fixed radius of 26 cm, the variation of sensitivities are shown as a function of the following variables: slice thickness, patient port size, intercrystal septum dimensions, lower energy discriminator level, and coincidence fan angle. Simulation-generated sensitivity data are compared with experimental values for several tomographs andgood agreement is obtained. Discrepancies between two definitions used in experimentally determining scatter fractions are discussed. The Monte Carlo simulation shows that small radii rings have an effective count rate (quality factor) that is more than 90 percent of that for larger rings at low and moderate activity levels (=/< 0.25 muCi cm(-3)), contrary to what is predicted from analytical calculations. It is concluded that small radius rings are better suited for low dose-rate static studies, while larger radius rings are preferred for high dose-rate dynamic studies.
More Related Videos
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography