Related Concept Videos
UV–Vis Spectrometers
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
UV–Vis Spectroscopy: Molecular Electronic Transitions
In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this process,...
Interaction of EM Radiation with Matter: Spectroscopy
Electromagnetic (EM) radiation can be considered an oscillating electric and magnetic field propagating through a medium that can interact with matter in its path. The electric field in the radiation can interact with electrical charges in the atoms or molecules in the matter. On the other hand, the magnetic field can interact with the magnetic field in the atomic nucleus. The study of the interaction between electromagnetic radiation and matter is termed spectroscopy. Spectroscopy is the study...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
The Electromagnetic Spectrum
The electromagnetic spectrum consists of all the types of electromagnetic radiation arranged according to their frequency and wavelength. Each of the various colors of visible light has specific frequencies and wavelengths associated with them, and you can see that visible light makes up only a small portion of the electromagnetic spectrum. Because the technologies developed to work in various parts of the electromagnetic spectrum are different, for reasons of convenience and historical...
The Electromagnetic Spectrum
Electromagnetic waves are categorized according to their wavelengths and frequencies, giving the electromagnetic spectrum. These waves are classified as radio, infrared, ultraviolet, etc. Radio waves refer to electromagnetic radiation with wavelengths ranging from millimeters to kilometers. Radio waves are commonly used for audio communications (i.e., radios) and typically result from an alternating current in the wires of a broadcast antenna. They cover a broad wavelength range and are used...