Related Experiment Video
Updated: Jul 7, 2026

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
Variation of agreement in polyp size measurement between computed tomographic colonography and pathology assessment:
Samir Gupta1, Valerie Durkalski, Peter Cotton
1Division of Digestive and Liver Diseases, University of Texas Southwestern Medical Center at Dallas, Dallas, Texas 75390-8887, USA. samir.gupta@utsouthwestern.edu
Background & Aims:
Clinical management of polyps discovered by computed tomographic (CT) colonography depends on polyp size. However, size measured by CT colonography is an estimate, and its agreement with other measures is not well characterized. We hypothesized that size measurement by CT colonography varies substantially compared with measurement by other methods.
Methods:
We performed a secondary data analysis of a multicenter study of CT colonography in comparison with colonoscopy. Polyp size was determined by CT colonography, at colonoscopy, and measurement prefixation with a ruler. Agreement was assessed using descriptive statistics and Bland-Altman methodology.
Results:
Six hundred trial participants completed both tests. Ninety-five percent limits of agreement indicated that estimates of size by CT colonography were between 52% lower to 64% higher than prefixation polyp size estimates. Ninety-five percent limits of agreement stratified by categories of clinical importance indicated that estimates of size by CT colonography were between 44% lower to 84% higher for polyps 0.6 cm or smaller, 44% lower to 44% higher for polyps 0.6 to 0.9 cm, and 48% lower to 22% higher for polyps smaller than 0.6 cm, 44% lower to 44% higher for polyps 0.6 cm to 0.9 cm, and 48% lower to 22% higher for polyps larger than 0.9 cm compared with prefixation estimates. Analysis of participants with 1 identified polyp in the same colon segment showed that categorization based on CT colonography measurement (ie, <0.6 cm, 0.6-0.9 cm, or >0.9 cm) differed from prefixation measurement for 43% of participants.
Conclusions:
Polyp size estimation by CT colonography varies from prefixation and colonoscopic measures of size. Future studies should clarify whether size estimation by CT colonography is sufficiently reliable as a primary factor to guide clinical management.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...