Evaluation of the unscanned soft-tissue thermal index
1Dept. of Electr. and Comput. Eng., Illinois Univ., Urbana, IL.
Abstract:
The monopole-source solution was used to calculate the three-dimensional complex acoustic pressure field for focused circular apertures in a medium having homogeneous acoustic and thermal properties. The three source diameters were 1, 2, and 4 cm and the eight transmit f-numbers (ratio of the radius of curvature/source diameter) were 0.7, 1.0, 1.3, 1.6, 2.0, 3.0, 4.0, and 5.0. For these focused field geometries, eight ultrasonic frequencies were evaluated (1, 2, 3, 4, 5, 7, 9, and 12 MHz) from which the three-dimensional temperature distribution was calculated using the bio-heat transfer equation in homogeneous, perfused media (attenuation=absorption=0.3 dB/cm-MHz; perfusion length: 1.0 cm). For each of the 192 cases, the acoustic field was normalized to the derated spatial peak, temporal average intensity (I(SPTA.3)) of 720 mW/cm(2), the maximum value allowed by the FDA 510(k) diagnostic ultrasound equipment approval process. Using the normalized acoustic field, the axial temperature increase profiles and the maximum temperature increases (DeltaT(max)) were determined for each case. Also, from the normalized acoustic field, the unscanned soft-tissue thermal index (TIS) was determined. In general, DeltaT(max), TIS, and source power increase with increasing transmit f-number, source diameter, or frequency. The TIS generally underestimates (is less than) DeltaT(max) for f-numbers =2, conditions for which DeltaT(max)=0.30 degrees C and TIS=0.40. This suggests that, for transmit f-numbers =2, TIS would not need to be displayed according to the ODS display requirements. With the exception of the longer-focus, larger-diameter, higher-frequency sources, TIS generally tracks DeltaT(max) for f-numbers >/=3. These exceptions suggest a breakdown of the ODS procedures far calculating TIS.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...