Related Experiment Video
Updated: Jul 7, 2026

Semi-Automated Analysis of Peak Amplitude and Latency for Auditory Brainstem Response Waveforms Using R
Published on: December 9, 2022
Spectral integration and wideband analysis in gap detection and overshoot paradigms
Joseph W Hall1, Emily Buss, John H Grose
1Department of Otolaryngology/Head and Neck Surgery, University of North Carolina School of Medicine, Chapel Hill, North Carolina 27599, USA. jwh@med.unc.edu
Abstract:
Several listening conditions show that energy remote from a target frequency can deleteriously affect sensitivity. One interpretation of such results entails a wideband analysis involving a wide predetection filter. The present study tested the hypothesis that both temporal gap detection and overshoot results are consistent with a wideband analysis, as contrasted with statistical combination of information across independent channels. For gap detection, stimuli were random or comodulated 50-Hz-wide noise bands centered on 1000, 1932, 3569, and 6437 Hz. For overshoot, the masker was an 8-kHz low-pass filtered noise, with 5-ms tone bursts presented at the same center frequencies used for gap detection. Signals were presented with either 0- or 250-ms delay after masker onset. In each paradigm, the target was introduced at only one frequency or at all four frequencies. Results from gap detection conditions did not favor a wideband analysis interpretation: Results in the random condition were consistent with an optimal combination of cues across frequency. An across-channel interference effect was also evident when only one of the four bands contained the gap. Although results from the overshoot conditions were consistent with a wideband analysis interpretation, they were more parsimoniously accounted for in terms of statistical combination of information.
Related Concept Videos
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
Bandpass Sampling
A bandpass signal has a spectrum with a lower frequency limit, denoted as ω1, and an upper frequency limit, denoted as ω2. The spectrum...
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original signal...
¹H NMR Signal Integration: Overview
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
