Related Experiment Video
Updated: Jul 7, 2026

Patch Clamp and Perfusion Techniques for Studying Ion Channels Expressed in Xenopus oocytes
Published on: January 10, 2011
Maitotoxin induces two dose-dependent conductances in Xenopus oocytes. Comparison with nystatin effects as a pore
Waskar Egido1, Vicente Castrejón, Benito Antón
1Laboratorio de Cronobiología, Departamento de Fisiología, Facultad de Medicina, UNAM, Mexico.
Abstract:
Maitotoxin (MTX)-induced conductances in Xenopus oocytes were thoroughly characterized using the two-electrode voltage clamp technique with a hyperpolarizing voltage protocol. MTX 5-100pM induced an inward current with maximal amplitude between 0.1 and 10microA. The kinetics of this current had rising and decaying phases, which were non-voltage dependent. Its reversal potential (Erev) was close to 0mV in high K+ or Na+ external solution, indicating the participation of non-selective cation channels (NSCC). A second conductance was developed at MTX doses higher than 200pM whose amplitude increased continuously. This current showed a large instantaneous component and a voltage-independent decay, as well as similar selectivity for Na+ and K+ ions (Erev approximately 0 mV). Moreover, the maximal current amplitude was about 34% bigger in high K+ than in high Na+. The MTX effect was reversible at all doses in pM range. All the properties found are similar to those of NSCC. The differences in the current kinetics suggest that the MTX-elicited currents reflect the activation of two sets of voltage-independent NSCC. As MTX has been proposed to act by forming pores directly into the plasma membrane, we compared its effects with those of nystatin, a well-known membrane pore inductor. We found strong differences between the effects of both substances suggesting different mechanisms for these drugs.
More Related Videos
12:48Measuring Cation Transport by Na,K- and H,K-ATPase in Xenopus Oocytes by Atomic Absorption Spectrophotometry: An Alternative to Radioisotope Assays
Published on: February 19, 2013
12:09Yeast Luminometric and Xenopus Oocyte Electrophysiological Examinations of the Molecular Mechanosensitivity of TRPV4
Published on: December 31, 2013
Related Concept Videos
Resting Membrane Potential
The Inside of a Neuron is More Negative
The membrane potential of a cell can be measured by inserting a microelectrode into a cell and comparing the charge to a reference electrode in the extracellular fluid. The...
The Resting Membrane Potential
Ligand-Gated Ion Channel Receptor: Gating Mechanism