On-line early fault detection and diagnosis of municipal solid waste incinerators

Jinsong Zhao1, Jianchao Huang, Wei Sun

  • 1College of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China. jinsongzhao@mail.tsinghua.edu.cn

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Microbial Wastewater Treatment01:30

Microbial Wastewater Treatment

Microbial communities in aquatic ecosystems play a key role in the natural breakdown of contaminants introduced through domestic and industrial effluents. Acting as biological catalysts, these microbes change and mineralize a wide range of organic and inorganic pollutants under different redox conditions.In oxygen-rich surface waters, aerobic heterotrophs lead organic matter breakdown, using oxygen as the terminal electron acceptor to efficiently oxidize substrates to carbon dioxide and water.
Biological Treatment of Effluent and Waste Water01:30

Biological Treatment of Effluent and Waste Water

Biological wastewater treatment relies on the metabolic activity of microorganisms to remove pollutants from sewage. In modern treatment systems, this process is organized into sequential stages that progressively reduce solid material, dissolved organic matter, and microbial contamination. Each stage plays a distinct role in improving water quality and preparing the effluent for safe discharge or reuse.Primary and Secondary TreatmentPrimary treatment is a physical process that removes large...
Reclosers and Fuses01:26

Reclosers and Fuses

Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.