Related Experiment Video
Updated: Jul 7, 2026

Optimization of Transesophageal Atrial Pacing to Assess Atrial Fibrillation Susceptibility in Mice
Published on: June 29, 2022
[Novel diagnostic possibilities of transesophageal stress echocardiography with electrical atrial pacing]
Abstract:
In order to develop simple technique of combination of transesophageal echocardiography (TEE) and transesophageal pacing, to create algorithm and protocol of transesophageal stress-echocardiography, and to study possible complications and methods of their elimination we examined 39 subjects (mean age 50 +/- 7.2 years) with suspected ischemic heart disease (IHD), 22 patients with arterial hypertension, 11 patients with episodes of ischemic changes on 24 hour ECG. In 11 patients with high blood pressure (BP) and 2 patients with frequent ventricular extrasystoles veloergometry was contraindicated, and in 3 patients veloergometry was not informative due to complete left bundle branch block. We suggested a device for simultaneous transesophageal echocardiography (TEE) and transesophageal pacing which consisted of transesophageal multiplane ultrasound cardiological transducer and electrode for transesophageal pacing. During test pacing frequency was increased stepwise from 120 140 and to 160 beats per min until appearance of ischemia or achievement of submaximal heart rate (HR). During intubation of esophagus HR and systolic BP increased from 80.2 +/- 11.5 to 102 +/- 12.5 b/min and from 130 +/- 23.6 to 149.1 +/- 17.5 mm Hg, respectively. Magnitude of double product rose from 104.4 +/- 29.4 to 149.4 +/- 32.3. This served as additive stress factor, facilitating more precise diagnosis of IHD. As a result various derangements of regional myocardial contractility were revealed in 14 patients (36%). These derangements were accompanied with ischemic ECG changes in 72% and with mitral regurgitation - in 43% of cases. The test was stopped prematurely in 1 patient because of paroxysm of reciprocal atrioventricular tachycardia. Simplicity of the proposed device, lack of complications allow to recommend it for clinical application. Anatomical proximity of esophagus and the heart, average 20 mm Hg elevation of BP, rising cumulative myocardial oxygen requirements augment reliability of the method in diagnostics of IHD.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Dysrhythmias V: Evaluating Dysrhythmias
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias

