Related Experiment Video
Updated: Jul 7, 2026

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Dissimilar or orthogonal reversed-phase chromatographic systems: A comparison of selection techniques
M Dumarey1, R Put, E Van Gyseghem
1Department of Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel - VUB, Laarbeeklaan 103, B-1090 Brussels, Belgium.
Abstract:
Developing an analytical separation procedure for an unknown mixture is a challenging issue. An important example is the separation and quantification of a new drug and its impurities. One approach to start method development is the screening of the mixture on dissimilar chromatographic systems, i.e. systems with large selectivity differences. After screening, the most suited system is retained for further method development. In a step prior to such strategy dissimilar chromatographic systems need to be selected. In this paper the performance of different chemometric selection approaches, described in the literature, was visually evaluated and compared. Additionally, orthogonal projection approach (OPA) was tested as another potential selection method. All techniques, including the OPA method, were able to select (a set of) dissimilar chromatographic systems and many similarities between the selections were observed. However, the Kennard and Stone algorithm performed best in selecting the most dissimilar systems in the earliest steps of the selection procedure. The generalized pairwise correlation method (GPCM) and the auto-associative multivariate regression trees (AAMRT) were also performing well. OPA and weighted pair group method using arithmetic averages (WPGMA) are less preferable.
Related Concept Videos
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Principles Of Column Chromatography