Related Experiment Video
Updated: Jul 7, 2026

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Accidental gamma dose measurement using commercial glasses.
Pradeep Narayan1, S G Vaijapurkar, K R Senwar
1Defence Laboratory, Ratanada Palace, Jodhpur 342 011, India. pradeep_narayan@rediffmail.com
Commercial glasses can measure accidental gamma radiation doses using Thermoluminescent (TL) techniques. These glasses offer a reliable method for dosimetry, even years after exposure, aiding in radiation victim management.
Area of Science:
- Materials Science
- Radiation Dosimetry
- Nuclear Physics
Background:
- Thermoluminescent (TL) techniques are crucial for measuring radiation doses.
- Commercial glasses are readily available and potentially useful for dosimetry.
- Accurate dose assessment is vital for managing radiation exposure incidents.
Purpose of the Study:
- To investigate the suitability of commercial glasses for accidental gamma dose measurement using TL.
- To determine the dosimetric properties of these glasses, including sensitivity, linearity, and fading characteristics.
- To assess the potential application of these glasses in radiological accident scenarios and medical triage.
Main Methods:
- Thermoluminescence (TL) measurements were performed on various commercial glasses after gamma irradiation.
- The dose response linearity, lower detection limit, and measurement uncertainty were evaluated.
- TL fading rates were analyzed under room conditions over a period of 15 days.
Main Results:
- Commercial glasses demonstrated sensitivity for gamma dosimetry with a lower detection limit of 1 Gy.
- Linear dose response was observed in the range of 1-25 Gy with a measurement uncertainty of +/- 10%.
- TL fading followed an exponential decay pattern, with 10-20% fading in 24 hours and up to 50% in 15 days, allowing for long-term dosimetry.
Conclusions:
- Commercial glasses are effective TL dosimeters for accidental gamma dose assessment.
- Their ease of use and immediate reading capability facilitate medical triage of radiation-exposed individuals.
- These glasses can serve as valuable tools for dosimetry in radiological accidents and for indicating lethal doses.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Biological Effects of Radiation
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Determination of Crystal Structures