Related Experiment Video
Updated: Jul 7, 2026

06:39
Improvement of Bacillus subtilis Spore Enumeration and Label Analysis in Flow Cytometry
Published on: June 30, 2023
An efficient analytical method for particle counting in evaluating airborne infectious isolation containment using
David L Johnson1, Robert A Lynch
1Department of Occupational and Environmental Health, University of Oklahoma Health Science Center, Oklahoma City, Oklahoma 73126-0901, USA. David-Johnson@ouhsc.edu
Journal of Occupational and Environmental Hygiene
|February 21, 2008
Summary
A new particle-based method accurately measures airborne particle escape from patient isolation enclosures. This simple, cost-effective technique enhances healthcare safety by verifying containment performance.
Area of Science:
- Environmental Health
- Infectious Disease Control
- Biomedical Engineering
Background:
- Patient isolation enclosures are critical for preventing healthcare-associated infections.
- Current tracer gas methods for assessing enclosure containment are complex and require specialized training.
- A simpler, accurate method is needed to quantify airborne particle leakage from isolation rooms.
Purpose of the Study:
- To develop and validate a particle-based technique for measuring the containment performance of patient isolation enclosures.
- To provide a simple, accurate, and precise method for assessing airborne particle escape.
- To enable verification of containment in expedient surge capacity enclosures.
Main Methods:
- Utilized micrometer-sized fluorescent polystyrene latex microspheres as surrogates for pathogenic bioaerosols.
- Released particles into isolation enclosures and sampled air inside and outside.
- Quantified captured particles on filters using an optimized random field counting approach.
Main Results:
- The particle-based technique accurately estimated surrogate bioaerosol particle counts on filters.
- Calculations of airborne particle concentrations and containment efficiency were precise.
- The method demonstrated specificity, sensitivity, and accuracy.
Conclusions:
- The developed particle-based technique offers a simple, accurate, and cost-effective solution for assessing patient isolation enclosure containment.
- This method can be implemented with generally available equipment and inexpensive supplies.
- It provides a reliable means to protect healthcare workers, patients, and visitors by verifying containment performance.