A computerized system for measuring the acoustic output from diagnostic ultrasound equipment
1Int. Sonic Technol. Inc., Horsham, PA.
Abstract:
The measurement arrangement, which complies with the requirements of the US Food and Drug Administration, consists of a positioning system with a full range of degrees-of-freedom and a digital oscilloscope, both under complete computer control. The acoustic pressure-time waveform is recorded using membrane-type and needle-type polyvinylidene fluoride (PVDF) hydrophone probes. The overall bandwidth of the system depends on the hydrophone probe used and can range up to 100 MHz. A complete description of the system and the measurement procedures is given, along with a brief discussion of the various factors which affect measurement uncertainty. The largest overall uncertainty of the same associated with acoustic intensity measurements was determined to be no greater than 20% for I(sppa) and 25% for I(spta) (spatial peak pulse average intensity and spatial-peak temporal-average intensity, respectively). Other applications of the system include transducer characterization and research work in ultrasound dosimetry and bioeffects.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...