Unsupervised Multi-Sensor Condition Monitoring of AODD Pump Systems Using Physics-Informed Health Indices and
Seong-Wook Kim1, Akeem Bayo Kareem1, Jang-Wook Hur1
1Department of Mechanical Engineering (Department of Aeronautics, Mechanical and Electronic Convergence Engineering), Kumoh National Institute of Technology, 61 Daehak-ro, Gumi-si 39177, Gyeongsangbuk-do, Republic of Korea.
Abstract:
Air-operated double-diaphragm (AODD) pumps in industrial sludge transfer suffer from gradual performance degradation due to rheological variations and component wear, yet conventional monitoring relies on scarce labeled fault data. This paper presents an unsupervised multi-sensor framework that requires no fault labels, integrating physics-informed dual health indices, HI-P (sludge load) and HI-V (mechanical stress), with a Gaussian Mixture Model anomaly detector and a physics residual attribution module. Governing equations motivate the use of these indices from five sensors: inlet and outlet flow meters (100 Hz), an air pressure transducer (100 Hz), and inlet and outlet accelerometers (1652 Hz). Trained on one healthy baseline day (86,218 one-second windows), the Gaussian Mixture Model achieves 100% day-level classification performance on the evaluated dataset (F1 = 1.00) across 455,201 test windows from nine operating days, with window-level receiver operating characteristic area under the curve (ROC-AUC) = 0.8580 and precision-recall AUC (PR-AUC) = 0.9082. Residual attribution analytically confirms that pressure residuals drive Episode 1 (HI-P peak 3.63 times baseline, Cohen's d = 1.70) and vibration residuals drive Episode 2 (HI-V peak 5.44 times the baseline, d = 4.10), providing empirical support for the proposed physics-informed formulation without requiring fault labels. Comparisons with four unsupervised benchmarks confirm that this is the only approach that simultaneously enables label-free operation, physics-driven features, exact attribution, real-world deployment, and perfect day-level F1.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...