Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
A new oscillometric method for assessment of arterial stiffness: comparison with tonometric and piezo-electronic
Johannes Baulmann1, Ulrich Schillings, Susanna Rickert
1University Clinic Bonn, Department of Internal Medicine, Division of Hypertension and Vascular Medicine, Bonn, Germany.
Introduction:
Pulse wave velocity (PWV) and augmentation index (AIx) are parameters of arterial stiffness and wave reflection. PWV and AIx are strong indicators for cardiovascular risk and are used increasingly in clinical practice. Previous systems for assessment of PWV and AIx are investigator dependent and time consuming. The aim of this study was to validate the new oscillometric method (Arteriograph) for determining PWV and AIx by comparing it to two clinically validated, broadly accepted tonometric and piezo-electronic systems (SphygmoCor and Complior).
Design And Method:
PWV and AIx were measured up to five times in 51 patients with the SphygmoCor, Complior and Arteriograph. In 35 patients, the measurements were repeated after 1 week in a second session using the same protocol.
Results:
The correlations of the PWV as assessed with the Arteriograph with the values obtained using the SphygmoCor (r = 0.67, P < 0.001) and the Complior (r = 0.69, P < 0.001) were highly significant. Variability and reproducibility for PWV were best for the Arteriograph, followed by Complior and SphygmoCor. AIx (SphygmoCor versus Arteriograph) were very closely correlated (r = 0.92, P < 0.001).
Perspectives:
The Arteriograph is a new, easy-to-use and time-effective method for assessing arterial stiffness and wave reflection.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement