Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Aortic Pulse Wave Velocity Determined with Oscillometric Pulse Wave Analysis Algorithm Antares Is an Independent
Marcus Dörr1,2, Harald Lapp3, Stefan Richter4
1Department of Internal Medicine B, University Medicine Greifswald, 17475 Greifswald, Germany.
Abstract:
Background/Objectives: Aortic pulse wave velocity (aPWV) is a well-established surrogate marker of arterial stiffness. The Antares algorithm offers a method for determining aPWV from oscillometric blood pressure waveforms without requiring additional inputs. This prospective study aimed to evaluate the association and prognostic value of aPWV, determined by Antares, in predicting major adverse cardiovascular events (MACE). Methods: In total, 240 patients (median age 69, 25.4% female) underwent oscillometric blood pressure measurements, from which aPWV was calculated using the Antares algorithm. MACE, comprising myocardial infarction, stroke, or all-cause mortality, occurred in 19.2% of patients during a median follow-up of 43 months. Survival analyses were performed using continuous aPWV values, a 10 m/s threshold, and aPWV quartiles. Kaplan-Meier curves and log-rank tests were used to compare survival across aPWV groups. Cox proportional hazards models were applied to assess the independent predictive value of aPWV. Results: Patients with aPWV < 10 m/s showed significantly higher event-free survival compared to those with aPWV ≥ 10 m/s (log-rank p = 0.044). Quartile analysis reinforced this, with the highest event rate in the highest aPWV quartile (log-rank p < 0.01). Multivariable analysis confirmed aPWV as an independent predictor of MACE (HR per 1 m/s: 1.24, 95% CI: 1.08-1.41; HR per 1 SD: 1.53, 95% CI: 1.17-2.00, p = 0.002). Adding aPWV to a risk model improved predictive accuracy (C-index 0.68 to 0.71). Conclusions: In the investigated cohort, aPWV derived using the Antares algorithm is an independent predictor of cardiovascular events. This non-invasive approach is promising for improving simple outpatient risk stratification and targeting preventive measures.
Related Concept Videos
Pulse
The pulse serves as a clinical...
Blood Pressure
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation