Related Experiment Video
Updated: Jul 7, 2026

A Novel Arthroscopic Medial Knot-Tying Suture-Bridge Repair with Rip-Stop Technique for Rotator Cuff Tears
Published on: January 13, 2026
Evaluation of suture abrasion against rotator cuff tendon and proximal humerus bone
Marc S Kowalsky1, Samuel G Dellenbaugh, David B Erlichman
1Center for Shoulder, Elbow, & Sports Medicine, Department of Orthopaedic Surgery, Columbia University, New York, New York, USA. msk@nyp.org
Purpose:
This study evaluates the abrasion properties of different suture materials through the rotator cuff tendon and proximal humerus tuberosity bone.
Methods:
Three types of sutures were compared: monofilament polypropylene, braided polyester, and braided polyblend polyester with a polyethylene core. For soft-tissue testing, the suture was passed through the infraspinatus tendons of 11 cadaveric shoulders. The suture was cycled with a fixed load, and the migration of the suture as it cut through the tissue was measured at intervals of 5 cycles, for a total of 50 cycles. For tuberosity testing, the sutures were passed through a transosseous tunnel created in the lesser tuberosity, and the suture was cycled with a fixed load until suture failure occurred.
Results:
On soft-tissue testing, the monofilament suture showed the least amount of abrasion, followed by the braided polyblend and then the braided polyester suture (cutting rate of 0.06 +/- 0.11 mm/cycle, 0.99 +/- 0.44 mm/cycle, and 1.75 +/- 0.91 mm/cycle, respectively; P < .0001). On tuberosity testing, suture breakage for the braided polyblend suture occurred at 501.3 +/- 220.4 cycles. The braided polyester and monofilament sutures broke after 256.6 +/- 120.9 and 193.5 +/- 144.8 cycles, respectively. The difference between cycles to failure of the polyblend and latter 2 sutures was statistically significant (P < .0001).
Conclusions:
This study shows increased abrasion properties for braided sutures compared with monofilament sutures, as well as different abrasion properties among different types of braided sutures. Furthermore, the braided polyblend suture showed significantly increased cycles before suture failure through a transosseous tunnel.
Clinical Relevance:
Although development of new suture materials has increased their failure strength, further advancements in suture material design should focus on decreasing soft-tissue abrasion properties and increasing strength to suture failure when cycled through bone.
Related Concept Videos
Bones of the Upper Limb: Humerus
Muscles that Move the Arm
The pectoralis major has two origins. Its clavicular head originates on the medial half of the clavicle. In contrast, the sternocostal head originates on the costal cartilages of ribs 1-6, the sternum, and the aponeurosis of the external oblique of the...
