Related Experiment Video
Updated: Jul 7, 2026

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Novel on-column and inverted operating modes of a microcounter-current flame ionization detector
Taylor C Hayward1, Kevin B Thurbide
1Department of Chemistry, University of Calgary, 2500 University Drive, NW, Calgary, Alberta T2N 1N4, Canada.
Abstract:
Improved operating modes of a microcounter-current flame ionization detector (microFID) are demonstrated. By operating the flame inside the end of a capillary gas chromatography (GC) column, the effective cell volume enclosing the flame is considerably reduced and results in significantly lower gas flows being required to produce optimal sensitivity from the stable flame. For instance, in this mode the tiny counter-current flame is situated "upside down" inside the column on the end of a stainless steel capillary delivering 4mL/min of oxygen and is stabilized by a counter flow of only 10mL/min of hydrogen carrier gas. Under these approximately fourfold reduced gas flow conditions, the microFID carbon response is linear over almost 5 orders of magnitude and yields a detection limit of 6x10(-10)gC/s. These figures agree well with those reported for the original microFID, which also similarly operated under hydrogen-rich conditions. To better simulate the oxygen-rich environment of a conventional FID flame, a novel "inverted" counter-current flow mode was also investigated. In this post-column microFID arrangement, a very lean flame is now situated on the end of a stainless steel capillary delivering 10mL/min of hydrogen, which is opposed by a counter-current flow of only 20mL/min of oxygen. The microFID detection limit obtained in this stable, oxygen-rich counter-current flame mode is 7x10(-11)gC/s with a response that is linear over almost 6 orders of magnitude. These findings are more comparable to those of a conventional FID. Overall, the low-flow sensitive microFID operating modes presented demonstrate that this detector may be potentially useful for adaptation to portable devices and related GC applications.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Flame Photometry: Overview
High-Performance Liquid Chromatography: Types of Detectors
Flame Photometry: Lab
Controlled-Current Coulometry: Overview