Related Experiment Video
Updated: Jul 6, 2026

Micro/Nano-scale Strain Distribution Measurement from Sampling Moiré Fringes
Published on: May 23, 2017
Intensity-modulated moiré topography
1Department of Systems and Human Science, Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama-cho, Toyonaka, Osaka 560-8531, Japan. lu@inolab.sys.es.osaka-u.ac.jp
Abstract:
Moiré topography has the advantage of requiring only a single image to obtain a three-dimensional measurement, but it cannot discern the fringe order. Because there is an ambiguity problem when calculating the depth range by use of fringe intensity or phase unwrapping, it is impossible to obtain an absolute phase and an absolute depth range. It is therefore difficult to discern the relation between fringes in the cases in which the fringes are discontinuous or the objects are isolated. An intensity-modulated moiré topography method is presented. By modulation of the transmission factors of the projection and the observation gratings by exponential functions a new moiré pattern whose fringe intensity changes with its order can be produced. The fringe order can be extracted easily from the fringe intensity, and the absolute range of the skeleton line can be obtained solely from its intensity. At the same time, we can segment the moiré pattern by its fringe order. For every segment the absolute phase and the absolute depth range of every point of the moiré pattern can be obtained solely from its intensity with no need for interaction with the user.
More Related Videos
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Methods of Obtaining Topography
Total Internal Reflection Fluorescence Microscopy
Super-resolution Fluorescence Microscopy
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Two-Dimensional Microscopy in Microbiology

