A fast nonrigid image registration with constraints on the Jacobian using large scale constrained optimization.

Michaël Sdika1

  • 1AIMS Group, Department of Neurology, University of California, San Francisco, San Francisco, CA 94107, USA. msdika@yahoo.fr

Summary

This study introduces a novel nonrigid image registration algorithm using B-splines. It effectively handles 3D image registration and prevents noninvertible transformations for accurate medical imaging analysis.

Related Concept Videos

Lagrange Multipliers: Two Constraints01:28

Lagrange Multipliers: Two Constraints

The method of Lagrange multipliers with two constraints is used to optimize a function subject to two independent constraints. In many applications, the objective function represents a quantity to be maximized or minimized, such as cost, area, distance, or energy. The two constraints represent requirements that the solution must satisfy, such as fixed volume, limited resources, or prescribed dimensions.For a function of three variables, each constraint forms a surface in three-dimensional space.
Lagrange Multipliers: One Constraint01:29

Lagrange Multipliers: One Constraint

In constrained optimization, the objective is to maximize or minimize a quantity while satisfying a fixed condition. A standard example is a rectangular pen built against a barn wall using 100 meters of fencing. Because the wall provides one side of the enclosure, only the other three sides require fencing. The problem is to find the dimensions that produce the greatest possible area.Let L represent the length parallel to the wall and W the width perpendicular to it. The area of the pen is A =...
Relative Motion Analysis using Rotating Axes-Problem Solving01:29

Relative Motion Analysis using Rotating Axes-Problem Solving

Consider a crane whose telescopic boom rotates with an angular velocity of 0.04 rad/s and angular acceleration of 0.02 rad/s2. Along with the rotation, the boom also extends linearly with a uniform speed of 5 m/s. The extension of the boom is measured at point D, which is measured with respect to the fixed point C on the other end of the boom. For the given instant, the distance between points C and D is 60 meters.
Here, in order to determine the magnitude of velocity and acceleration for point...
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
Relative Motion Analysis using Rotating Axes01:25

Relative Motion Analysis using Rotating Axes

Consider a component AB undergoing a linear motion. Along with a linear motion, point B also rotates around point A. To comprehend this complex movement, position vectors for both points A and B are established using a stationary reference frame.
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it instrumental in...
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution00:52

¹H NMR of Conformationally Flexible Molecules: Temporal Resolution

At room temperature, the chair conformer of cyclohexane undergoes rapid ring flipping between two equivalent chair conformers at a rate of approximately 105 times per second. These two chair conformers are in equilibrium. The rapid ring flipping results in the interconversion of the axial proton to an equatorial proton and an equatorial to the axial proton. Such interconversions are too rapid and cannot be detected on the NMR timescale. Hence, the NMR spectrometer cannot distinguish between the...