Related Experiment Video
Updated: Jul 6, 2026

Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
Line-pair selections for remote sensing of atmospheric ammonia by use of a coherent CO2 differential absorption lidar
1Environmental Research Laboratories, Atmospheric Lidar Division, National Oceanic and Atmospheric Administration, Cooperative Institute for Research in Environmental Sciences, University of Colorado-Boulder, Boulder, Colorado 80303, USA. yzhao@etl.noaa.gov
Abstract:
Research on wavelength selection of CO2 laser lines for range-resolved remote sensing of atmospheric ammonia by use of a coherent differential absorption lidar system is described. Four laser line pairs are suggested for different levels of ammonia concentrations from approximately a few parts per billion to 1 part per million in a polluted atmosphere. The most suitable line for measuring ambient ammonia concentrations is 9R(30), because it has the highest absorption coefficient. 10R(14) has the lowest absorption coefficient, making it suitable for strong source mapping. 10R(8) and 10P(32) are best for intermediate levels of ammonia concentration. Absorption coefficients of ammonia calculated from the HITRAN96 database are in good agreement (mostly within +/-10% )with other experimental results.Sensitivity of measurement, interference from water-vapor lines with typical humidity in the summer,and sensitivity of ammonia absorption cross section to temperature and pressure are analyzed and calculated for the four wavelength pairs. The results show that the interference from water-vapor lines is easily correctable to a negligible amount, and errors caused by uncertainties in temperature and pressure are insignificant.
Related Concept Videos
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Atomic Absorption Spectroscopy: Atomization Methods
NMR Spectroscopy Of Amines
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Atomic Emission Spectroscopy: Lab