Related Experiment Video
Updated: Jul 6, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Hydrophilic interaction liquid chromatography-tandem mass spectrometry determination of estrogen conjugates in human
Feng Qin1, Yuan-Yuan Zhao, Michael B Sawyer
1Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, University of Alberta, 10-102 Clinical Sciences Building, Edmonton, AB, Canada T6G 2G3.
Abstract:
We report a hydrophilic interaction liquid chromatography (HILIC) separation with tandem mass spectrometry (MS) detection method for analysis of seven urinary estrogen conjugates. HILIC separation employing a mobile phase with high organic solvent content resulted in enhanced electrospray ionization efficiency and MS sensitivity compared with reversed-phase (RP) LC-MS methods. Solid-phase extraction (SPE) was used to further improve the limit of detection and to eliminate interferences for the analysis of urine samples. No hydrolysis or derivatization was required in the sample pretreatment. This SPE/HILIC-MS/MS method provided limits of quantification (LOQs at S/N = 10) for the seven conjugates ranging from 2 to 1000 pg/mL with only 1 mL of urine sample, representing an improvement of 1 order of magnitude over the RPLC tandem MS methods previously reported. This method provided a linear dynamic range of 3 orders of magnitude, recovery of 92-109%, intraday accuracy of 84-109%, intraday precision of 1-14%, interday accuracy of 80-111%, and interday precision of 1-22%. We have successfully applied this technique to determine the seven estrogen conjugates in urine samples of a pregnant woman and found unique concentration changes of six estrogen conjugates at different stages of pregnancy while the concentration of estriol-3-glucuronide (E3-3G) remained constant. We further studied the profiles of individual estrogen conjugates in breast cancer patients before and after treatment and found patient-dependent effects of aromatase inhibitor treatment on estrogen phase-II metabolism, which have not been reported previously. This study demonstrates the potential clinical application of the HILIC-MS/MS technique for sensitive monitoring of the changes of urinary estrogen conjugates in a clinical setting.
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: