Assaying small-molecule-receptor interactions by continuous flow competitive displacement chromatography/mass
Jai Sharma1, Travis R Besanger, John D Brennan
1Department of Chemistry, McMaster University, Hamilton, Ontario L8S 4M1, Canada.
Abstract:
Small-molecule screening techniques that employ mass spectrometry detection have been highly successful. However, the inability of conventional techniques, such as frontal affinity chromatography-mass spectrometry (FAC-MS), to easily identify weak binding molecules (i.e., Kd >or= 1 microM) using small amounts of target protein (subpicomole levels) represents a significant impediment to the widespread use of the method in the routine screening of low-abundance membrane receptors. This limitation is particularly notable in the early stages of the drug discovery process, as weak binding molecules can serve as useful leads for targets with no known ligand or when existing tight binding ligands have little therapeutic value. Competitive assay methods involving the displacement of an indicator ligand offer a more sensitive alternative, as the ability to generate an appreciable signal through various methods, including transient overconcentrations of indicator compounds, provides an unambiguous means for identifying weak affinity ligands. In this work we describe a continuous flow competitive assay based on the principles of FAC-MS that can be widely used to identify and characterize weak affinity ligands using low levels of the nicotinic acetylcholine receptor from Torpedo californica (nAChR). The validity of the assay is shown through the ability to identify nicotine (Kd approximately 1 microM) with columns containing <2 pmol of binding sites. Multiple injections of nicotine on a single column produce reproducible peaks in the signal of the indicator compound, epibatidine (Kd approximately 2 nM) showing minimal degradation in signal intensity between trials. The intensity of the peaks is dependent on the concentration of nicotine being injected, and binding curves can be generated through multiple injections on the same column. We investigate and optimize various parameters, including assay speed and concentrations, and demonstrate an automated assay format with the potential for use as a high-throughput screening tool. The ability to screen for weak binders of more pharmacologically relevant membrane receptors in a high-throughput screening format is discussed.
More Related Videos
06:56A Flow Cytometry-based Assay to Identify Compounds That Disrupt Binding of Fluorescently-labeled CXC Chemokine Ligand 12 to CXC Chemokine Receptor 4
Published on: March 10, 2018
08:06Absolute Quantification of Cell-Free Protein Synthesis Metabolism by Reversed-Phase Liquid Chromatography-Mass Spectrometry
Published on: October 25, 2019
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
High-Performance Liquid Chromatography: Types of Detectors
Affinity Chromatography
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...