Detection limit estimator for multivariate calibration by an extension of the IUPAC recommendations for univariate
Miren Ostra1, Carlos Ubide, Maider Vidal
1Departamento de Química Aplicada, Facultad de Química, Universidad del País Vasco, Apartado 1082, 20080 San Sebaastián, Spain.
Abstract:
A methodology is proposed to estimate the limit of detection (LOD) of analytical methods when multivariate calibration is applied. It tries to follow the same premises as the IUPAC methodology for univariate calibration. The mathematical support is given and algorithms such as partial least squares (PLS) regression, PLS2 and principal component regression (PCR) are used. Only multivariate raw data are used; that is, no surrogate univariate signal is deduced. Non-linearities are allowed. Near infrared (NIR) data of 5 component pseudo-gasoline samples together with simulated fluorescence synchronous spectra of binary mixtures (first order data) are used for evaluation. Experimental verification is performed using different kinds of data, namely: binary mixtures of bentazone and fenamiphos (very overlapped spectra, second order data) obtained by sequential injection (SI), and kinetic data of the reaction between the Fenton's reagent (FR) and pesticides such as atrazine, bentazone and alachlor (individual or binary mixtures, second order data). Results are always compared with independent methods previously proposed in the literature, based in the use of surrogate univariate signals. In general, similar results are found and no statistically significant differences seem to be present, except in a few cases when complex chemical systems are involved.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
10:25Construction of Models for Nondestructive Prediction of Ingredient Contents in Blueberries by Near-infrared Spectroscopy Based on HPLC Measurements
Published on: June 28, 2016
Related Concept Videos
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Calibration Curves: Correlation Coefficient