Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
Characterization of volatile components in dry chrysanthemum flowers using headspace-liquid-phase microextraction-gas
Guoqing Wang1, Chunhong Dong, Yu-an Sun
1Department of Applied Chemistry, Zhengzhou University of Light Industry, Zhengzhou, Henan, 450002, China. gqwang@ustc.edu
Abstract:
A headspace-liquid-phase microextraction (HS-LPME)-GC (gas chromatography) method for the characterization of volatile components in dry chrysanthemum flowers has been developed. In the proposed method, two extraction solvents, n-hexadecane and benzyl alcohol, are used for preconcentrating volatiles in the sample. A droplet of the extraction solvent is squeezed from the GC syringe and inserted in the headspace of the sample bottle with the dry flower, immersed in deionized water, and warmed in a water bath. The optimum HS-LPME parameters in terms of extraction solvent type, droplet magnitude, equilibrium (water bath) temperature, equilibrium time, extraction time, and ionic strength are achieved using GC-FID (flame ionization detection) by varying several levels of the factors that affect the HS-LPME procedure. After extraction under the optimized conditions, the extraction droplet is retracted into the syringe and injected for GC-MS (mass spectrometry) analysis. Thirty-three volatile components are extracted and identified using this HS-LPME-GC-MS method, with the aid of chemometric methods. It is shown that the volatiles in dry chrysanthemum flowers are mainly unsaturated organic compounds, such as monoterpenes, sesquiterpenes and their oxygenous derivatives, triterpenoids, and aliphatic compounds. Several representative components, in order of precedence of the retention time, are pinene (106.3 microg/g), camphene (112.7 microg/g), eucapyptol (52.1 microg/g), camphor (29.4 microg/g), borneol (4.2 microg g), bornyl acetate (67.3 microg/g), caryophyllene (0.7 microg/g), and caryophyllene oxide (20.0 microg/g). The relative standard error and detection limit of this method is 5-9% and 0.4 microg/g, respectively.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Volatilization
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-II
Chromatographic Methods: Terminology