Related Experiment Video
Updated: Jul 6, 2026

Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Single drop micro-extraction with O,O-diethyl dithiophosphate for the determination of lead by electrothermal atomic
Heloísa França Maltez1, Daniel L G Borges, Eduardo Carasek
1Departamento de Química, Universidade Federal de Santa Catarina, Campus Universitário Trindade, 88040-900 Florianópolis, SC, Brazil.
Abstract:
Lead was extracted as the O,O-diethyldithiophosphate (DDTP) complex from aqueous solution into a drop of CHCl(3) immersed in the solution. Unlike previously reported procedures using single drop micro-extraction (SDME) for the extraction of inorganic analytes, the complexation reaction was conducted in the aqueous phase, as the ammonium salt of DDTP is soluble in water. The concentration of DDTP was optimized as 0.01% (m/v). Experimental parameters such as extraction time (7min) and organic drop volume (3microL) were optimized and selected as a compromise between sensitivity and stability of the organic drop in the aqueous solution. The sensitivity with electrothermal atomic absorption spectrometry (ET AAS) was low, probably due to infiltration of the organic drop into the totally pyrolytic graphite platform. To overcome this problem, tungsten (400microg) was thermally deposited onto the platform surface. A short pyrolysis stage at 700 degrees C was included to reduce background absorption. Under these conditions, five certified reference materials with different characteristics were analyzed using calibration against aqueous standards submitted to the SDME procedure, resulting in good agreement between certified and found concentration values at a 95% confidence level. Two real water samples have also been analyzed, with recoveries ranging from 85 to 92% after enrichment with Pb. An enhancement factor of 52 allowed a detection limit of 0.2microg L(-1) or 0.04microg g(-1), demonstrating the high detection capability of the proposed procedure, with a relative standard deviation typically below 4%.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Extraction: Advanced Methods
Electrodeposition
Electrodeposition can...
Atomic Emission Spectroscopy: Overview
Atomic Absorption Spectroscopy: Atomization Methods
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...

