Related Experiment Video
Updated: Jul 6, 2026

Fentanyl Analog Screening using LC-TIMS-TOF MS/MS
Published on: November 8, 2024
Simultaneous stopped-flow determination of morphine and naloxone by time-resolved chemiluminescence
José A Murillo Pulgarín1, Luisa F García Bermejo, José M Lemus Gallego
1Department of Analytical Chemistry and Foods Technology, University of Castilla-La Mancha, 13071 Ciudad Real, Spain.
Abstract:
The first application of the flow analysis coupled with chemiluminescence detection and based on stopped-flow chemistry to the simultaneous determination of two components, using a two equation system, is described. The proposed method to determine simultaneously morphine and naloxone is based on the chemiluminescence oxidation of these compounds by their reaction with potassium permanganate in an acidic medium. The main feature of the system used is that the recording of the whole chemiluminescence intensity-versus-time profiles can be obtained, using the stopped-flow technique in a continuous-flow system. Then, the chemiluminescent signals obtained at two times of these profiles can be used to determine the concentration of both opiate narcotics. The effect of common emission enhancers on the chemiluminescence emission of these compounds in different acidic media, using the above-mentioned technique, was studied, in order to achieve the best conditions in which, the CL profiles of both compounds should be additive. The parameters selected were sulphuric acid 1.0 mol L(-1), permanganate 0.2 mmolL(-1) and formaldehyde 0.8 mol L(-1). Taken in account the different profiles of the transient CL signal obtained with each compounds, using the selected chemical conditions, two measurement times (1.4 and 4.8s) of these responses curves were considered with the purpose to establish a simple 2 x 2 matrix calculation. Using the chemiluminiscent signals obtained at these times, a linear calibration graph was obtained for each one of the compounds between 0.01 and 1.00 mg L(-1) for morphine and 0.10-1.50 mg L(-1) for naloxone. The present chemiluminescence procedure was applied to the determination of both compounds in mixtures and was found to be satisfactory.
More Related Videos
08:57Sample Extraction and Simultaneous Chromatographic Quantitation of Doxorubicin and Mitomycin C Following Drug Combination Delivery in Nanoparticles to Tumor-bearing Mice
Published on: October 5, 2017
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Opioid Analgesics: Synthetic and Semisynthetic Opioids
Fast Reactions
Opioid Analgesics: Morphine and Other Natural Cogeners
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the lowest drug...