Related Experiment Video
Updated: Jul 6, 2026

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
The accuracy of preload assessment by different transesophageal echocardiographic techniques in patients undergoing
Christoph K Hofer1, Michael T Ganter, Andreas Rist
1Institute of Anesthesiology and Intensive Care Medicine, Triemli City Hospital Zurich, Zurich, Switzerland.
Objectives:
The aim of this study was to compare the following approaches to assess left ventricular preload by transesophageal echocardiography (TEE): left ventricular end-diastolic volume index (LVEDVI) determined by using the method of disc summation (LVEDVI(Md)) and left ventricular end-diastolic area index (LVEDAI) were compared with LVEDVI assessed by the modified Simpson formula (LVEDVI(Si)). Global end-diastolic volume index (GEDVI) and stroke volume index (SVI) measured by the PiCCO(plus) system (Pulsion Medical Systems, Munich, Germany) were used as TEE-independent reference variables.
Design:
Prospective observational study.
Setting:
Community hospital.
Participants:
Twenty-two patients undergoing elective cardiac surgery.
Interventions:
After the induction of anesthesia, hemodynamic assessment by TEE and the PiCCO(plus) system was made 20 (T(1)) and 10 minutes (T(2)) before and 10 (T(3)) and 20 minutes (T(4)) after a fluid trial. At each time point, LVEDVI(Md), LVEDAI, LVEDVI(Si), GEDVI, and SVI were determined.
Measurements And Main Results:
The fluid trial resulted in a significant increase of all preload variables measured at T(3). At T(4), all preload variables but LVEDVI(Md) showed a significant decrease. The mean bias +/- 2 SD for percent changes (Delta) of LVEDVI(Md) - DeltaLVEDVI(Si) was 1.5% +/- 59.0% and for DeltaLVEDAI - Delta LVEDVI(Si) 0.9% +/- 23.6%. The correlation between LVEDVI(Md) and LVEDVI(Si) was significantly weaker than between LVEDAI and LVEDVI(Si) (p < 0.001). Comparing TEE measurements with GEDVI and SVI, strong correlations were observed for LVEDAI and LVEDVI(Si) only.
Conclusion:
The method of disc summation cannot be recommended for preload assessment during a fluid challenge in cardiac surgery patients. By contrast, single-plane area measurements provided reliable information when compared with the application of the modified Simpson formula.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Cardiomyopathy VII: Pre and Post Operative Nursing Management