No-alignment-strategies for exploring a set of two-way data tables obtained from capillary electrophoresis-mass
M Daszykowski1, R Danielsson, B Walczak
1Department of Chemometrics, Institute of Chemistry, Silesian University, 9 Szkolna Street, 40-006 Katowice, Poland.
Abstract:
Hyphenated techniques such as capillary electrophoresis-mass spectrometry (CE-MS) or high-performance liquid chromatography with diode array detection (HPLC-DAD), etc., are known to produce a huge amount of data since each sample is characterized by a two-way data table. In this paper different ways of obtaining sample-related information from a set of such tables are discussed. Working with original data requires alignment techniques due to time shifts caused by unavoidable variations in separation conditions. Other pre-processing techniques have been suggested to facilitate comparison among samples without prior peak alignment, for example, 'binning' and/or 'blurring' the data along the time dimension. All these techniques, however, require optimization of some parameters, and in this paper an alternative parameter-free method is proposed. The individual data tables (X) are represented as Gram matrices (XXT), where the summation is taken over the time dimension. Hence the possible variations in time scale are eliminated, while the time information is at least partly preserved by the correlation structure between the detection channels. For comparison among samples, a similarity matrix is constructed and explored by principal component analysis and hierarchical clustering. The Gram matrix approach was tested and compared to some other methods using 'binned' and 'blurred' data for a data set with CE-MS runs on urine samples. In addition to data exploration by principal component analysis and hierarchical clustering, a discriminant partial least squares model was constructed to discriminate between the samples that were taken with and without the prior intake of a drug. The result showed that the proposed method is at least as good as the others with respect to cluster identification and class prediction. A distinct advantage is that there is no need for parameter optimization, while a potential drawback is the large size of the Gram matrices for data with high mass resolution.
More Related Videos
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...