Abstract:
A personal dosemeter issued for individual monitoring is calibrated in terms of personal dose equivalent, usually H(P)(10). In general it yields a reasonable estimate of effective dose (E) when the exposed person does not wear protective clothing. In interventional cardiology, however, a lead equivalent apron is worn and often a thyroid collar. A correction factor will then be necessary to convert a dosemeter reading to E. To explore this factor an interventional cardiology procedure is simulated based on exposure conditions typical for a modern hospital in the BENELUX area. The dose to the cardiologist is investigated using Monte Carlo simulation of radiation transport. It is concluded that a personal dosemeter may best be worn outside the apron at a central position high on the chest for least dependence on the beam direction. It will overestimate E by roughly a factor of 20 (apron and thyroid collar of 0.25 mm Pb).
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization I: Pre-Procedure Overview
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Holter Monitor: 24-Hour Monitoring